Ambient Temperature
-40 to +70 °C (-40 to +158 °F). Minimum start-up temperature is -50 °C (-58 °F).
With LCD display: -25 to 70 °C (-13 to 158 °F).
Analog Input
One input channel, current range 0-23 mA.
Analog Output
One output channel (SIL certified ), current range 3.5-23 mA (HART).
Custody Transfer Approval
OIML R85:2008, and national certifications such as PTB, NMi etc.
Display/Interface
Integral digital read-out display: level, level rate, ullage, signal strength, volume (TOV), liquid average temperature, 1-16 spot temperature, vapor average temperature, ambient temperature, free water level, liquid pressure, vapor and air pressure, observed and reference density, and flow rate.
Emulation Capability
Possible to integrate with legacy tank gauging systems. Supports emulation of other vendors’ communication protocols. See “Field Bus” above.
Field Bus
Rosemount 2410 communicates with a host or a field communication unit via TRL2 Modbus, RS485, 4-20 mA/HART, Enraf, L&J Tankway, Varec Mark/Space, Whessoe, GPE, Sakura, Tokyo Keiso and WirelessHART® protocol.
Power Supply
• 24-48 VDC (-15% to +10%).
• 48-240 VAC (-15% to +10%), 50/60 Hz.
Relay Outputs
Two SIL certified relays, which can be configured for different tanks and process variables.
Safety
• SIL 2 and SIL 3 certified.
• TÜV tested and WHG approved for overfill prevention.
Tank Hub Versions
Single tank version: supports one Rosemount 5900S 2-in-1 gauge or two radar level gauges, type Rosemount 5300, 5408, or 5900 installed on the same tank.
Multiple tank version: for a Rosemount 5300/5408/5900 system configuration:
- The software supports 16 field devices and 10 tanks per hub.
- Maximum five Rosemount 5300 or ten 5408 per hub.
Tankbus
Foundation™ Fieldbus FISCO (self-configuring ).