Device Type
                                
                                
                                    Solenoid Coils
                                
                             
                            
                                
                                    On state Output rating
                                
                                
                                    22 V to 25 V (open circuit); 11 V at 45 mA
                                
                             
                            
                                
                                    Off state leakage Current
                                
                                
                                    230 µA
                                
                             
                            
                                
                                    Line Fault Test detection
                                
                                
                                    Guaranteed short circuit: <100 Ω load, Guaranteed good status: 150 Ω to 20 kΩ load, Guaranteed open circuit: >25 kΩ load
                                
                             
                            
                                
                                    Isolation
                                
                                
                                    Galvanically isolated according to EN 60079-11. Voltage peak value 375 VDC.
                                
                             
                            
                                
                                    CHARM power req.
                                
                                
                                    78 mA max @ 24 VDC ±10%
                                
                             
                            
                                
                                    CHARM Heat Dissipation
                                
                                
                                    1.4 W
                                
                             
                            
                                
                                    Configurable output behavior
                                
                                
                                    Momentary Output, Continuous Pulse Output, Line fault testing
                                
                             
                            
                                
                                    Line Fault Test timing
                                
                                
                                    180 to 220 µsec